Intrinsically Safe Humidity Sensor
Your Professional Intrinsically Safe Humidity Sensor Supplier
We supply electrical automation and safety equipment for coal mining applications, including intrinsically safe sensors and atmospheric monitoring devices. Our intrinsically safe humidity sensor category provides rugged measurement components designed for mine environmental monitoring, ventilation tracking, and automated data acquisition systems.
Selecting a mining-grade relative humidity (RH) sensor involves more than matching a basic measurement range. Engineering and procurement teams must evaluate long-term measurement stability, response time, electrical interfaces, operating temperature limits, and applicable safety certification to ensure reliable performance in underground coal mines or other hazardous industrial locations.
Technical Specifications Overview
|
Parameter |
Technical Specification (Example Model: HTS-EX200) |
|
Product Model |
HTS-EX200 Series |
|
Measured Parameter |
Relative Humidity (RH) and Temperature (Integrated) |
|
Humidity Range |
0% to 100% RH (Non-condensing) |
|
Accuracy |
+/- 3% RH (20% to 90% RH); +/- 0.5 deg C (Temperature) |
|
Response Time (t90) |
Less than 15 seconds (at 1m/s airflow) |
|
Operating Temperature |
-20 deg C to +60 deg C |
|
Power Supply |
DC 12V ~ 24V (Powered via certified intrinsically safe barrier) |
|
Output Signal |
4-20 mA current loop (Optional RS485 Modbus RTU) |
|
Ingress Protection |
IP65 (Robust anti-static aluminum alloy enclosure) |
|
Safety Approval |
Ex ib I Mb (Mining Intrinsic Safety) |
|
Mounting & Dimensions |
Wall-mounted / Duct insertion, 140 x 85 x 60 mm |
Why Source From Us?
Manufacturing Infrastructure
Production supported by CNC lathes, machining centers, laser cutting equipment, and dedicated assembly lines operating under an ISO 9001:2015 quality management framework.
Traceability and Quality Control
Rigorous component inspection, functional testing, and quality documentation available for project review.
Technical Support
Direct engineering assistance to match sensor specifications with your local regulatory frameworks and monitoring hardware.
Technical Selection Guide: How to Evaluate a Mining Humidity Sensor

Measurement Performance and Stability
Range and Tolerance: Verify whether the sensor covers the target RH range (typically 0% to 100% RH) and maintains accuracy under high-humidity or condensing conditions common in underground returns.
Drift and Calibration: Review long-term stability specifications to determine maintenance intervals and calibration requirements in remote or difficult-to-access locations.
Environmental Operating Limits and Protection
Temperature Compensation: Check if the sensor integrates temperature compensation to maintain humidity accuracy despite ambient thermal fluctuations.
Ingress Protection (IP Rating): Review the enclosure protection rating. While an IP rating defines resistance against dust and moisture ingress, it does not substitute for explosion protection certification.
Output Signals and System Integration
Signal Compatibility: Confirm whether the output matches your monitoring input requirements (e.g., analog current/voltage loops or digital communication protocols).
Cabling and Terminals: Evaluate cable entry points, terminal configurations, and maximum permissible cable lengths dictated by intrinsic safety loop resistance limits.
Intrinsic Safety Compliance & Associated Apparatus
Protection Concept: Ensure the unit is designed under the intrinsic safety concept, which limits electrical and thermal energy to prevent ignition in explosive atmospheres.
Associated Barriers: Confirm that the required associated apparatus (such as certified zener barriers or galvanic isolators) are factored into your loop design.
Certificate Scope: Confirm the exact model's certification body, safety markings, and permitted electrical parameters (Ui, Ii, Pi, Ci, Li).

Core Applications
Our intrinsically safe humidity sensors support multiple monitoring architectures within hazardous and industrial sectors:
Underground Mine Environmental Monitoring
Providing continuous relative humidity data as part of comprehensive safety and atmospheric monitoring networks.
Mine Ventilation Monitoring
Tracking moisture levels in intake and return airways to support ventilation planning and airflow analysis.
Mining Automation & Data Acquisition
Integrating humidity nodes into broader industrial bus networks for automated system responses.
OEM Equipment Integration
Supplying certified sensing elements to mining machinery manufacturers and system integrators requiring robust environmental inputs.
FAQ
As one of the most professional intrinsically safe humidity sensor manufacturers in China, we're featured by providing high quality products for mining communication system and mining automation equipment. Welcome to buy customized intrinsically safe humidity sensor from our factory.