I. Nozzle Maintenance: Key to Ensuring Atomization Efficiency
The nozzle is the most easily clogged component of the system, directly affecting dust reduction efficiency.
1. Regular Inspection and Cleaning
Inspect the nozzles daily for clogging, uneven spraying, or dripping; disassemble and clean them monthly using a specialized cleaning agent or ultrasonic equipment to remove scale and impurities.
2. Select Anti-Clogging Nozzles
We recommend using stainless steel nozzles with a self-cleaning structure to improve corrosion resistance and anti-clogging capabilities.
3. Replace Damaged Nozzles Promptly
Replace severely deformed or worn nozzles in groups to avoid uneven atomization.
II. Water Quality Management and Pretreatment: Reducing Clogging Risk at the Source
Water quality directly affects nozzle lifespan and system stability.
1. Install Multi-Stage Filtration Device
The system's built-in two-stage micron-level filtration significantly reduces the probability of clogging. It is recommended to install an additional pre-filter and water softener.
2. Regular Water Quality Testing: Monthly sampling and testing of suspended solids, hardness, and microbial content. If water quality is poor, pretreatment measures should be adjusted promptly.
3. Preventing Microbial Growth: Environmentally friendly bactericides can be added to closed water tanks, or ultraviolet disinfection devices can be used to control biofilm formation.
III. Pipeline System Maintenance: Ensuring Smooth Flow
Pipeline leaks or scale buildup will reduce pressure and affect overall spray performance.
1. Checking Sealing: Regularly check for loose or leaking pipe connections, tightening or replacing seals promptly.
2. Removing Deposits: Flushing main and branch pipes quarterly to remove internal silt and scale, maintaining smooth water flow.
3. Freezing and Corrosion Prevention: In cold seasons, surface systems must be drained of accumulated water to prevent freezing and cracking; underground systems in humid environments should use PE or stainless steel corrosion-resistant pipes.
IV. Electrical and Control System Maintenance: Ensuring Intelligent Operation
The control system is the core for achieving "automatic start/stop and联动感" (interlocking sensing).
1. Check Intrinsically Safe Circuit Safety: Quarterly test the insulation resistance and withstand voltage performance of intrinsically safe circuits to ensure compliance with GB 3836.4 standard.
2. Maintain Sensor Functionality: Clean dust sensor probes to avoid direct spray impact on detection accuracy; calibrate infrared sensor sensitivity.
3. Software Upgrade and Data Backup: Regularly update PLC control programs, optimize operating logic, and back up key parameters to prevent data loss.
V. Special Inspection of Explosion-Proof Components: Upholding the Safety Bottom Line
Intrinsically safe systems must continuously meet explosion-proof requirements.
1. Check the Integrity of Explosion-Proof Enclosure: Ensure that the control box and junction box are free of cracks and rust, all bolts are tightened, and the protection level reaches IP65 or higher.
2. Verify Safety Barrier Functionality: Check whether the Zener safety barrier grounding is reliable (<1Ω) and whether the isolated safety barrier signal transmission is normal.
3. Do Not Open Cover While Powered On: All maintenance operations must be performed with the power off and by qualified personnel to prevent sparks caused by misoperation.